Studio Transcend (10-12 users)

Modular Simulated Altitude, Infrared Heat, and Red Light Therapy Studio

  • Capacity: Suited for up to 12 users
  • Internal Dimensions: 36’ / 11,000 mm × 9’ / 2,750 mm × 7’10” / 2,400 mm
  • Floor Area: 325.6 ft² /30.25 m²
  • External Dimensions: 36’4” / 11,094 mm × 9’4” / 2,844 mm × 8’3” / 2,511 mm
  • Internal Volume: 2,564ft³ /72.6 m³
  • Indoor Weight: 2,998 lb /1,360 kg
  • Build a full performance center at home or in a facility
  • Includes our proprietary Young Hypoxic Wellness Method™
  • EXALT XP App: (subscription fees apply)
  • Models: Available in indoor and outdoor versions

Recommended Studio Equipment Combinations:

  • 10 STEPR Performance Series XL VPR cardio machines (including up to 2 TreadSleds).

INDOOR MODELS

  • Hemlock interior panels (premium wood finish)
  • Multi-layer insulation system
  • Sealed environmental envelope
  • Tempered-glass door
  • Anti-slip engineered floor
  • Clean interior routing for HVAC, IR, PBM
  • 2–3 hour residential install (typical)

Built on a high-integrity modular architecture, each Studio is a sealed chamber engineered for:

  • Simulated altitude: 20.9% → ~11.0% O₂ (equivalent to around 11,000-18,000 feet or 3,300 – 5,500 meters at altitude)
  • Infrared heat: 45℃/ 113℉
  • Red Light Therapy

The Studios are powered by the EXALT XP Control System (Distech ECY-350 platform), an Atlas Copco NGMs nitrogen generator, and 5-11 kW (7-15 hp) VSD air compressor all configured for the U.S. electrical installation environment.

Timeline

  • Typical studio installation: 1-3 days

EXALT XP STUDIO SITE INSTALLATION PARAMETERS

SPACE REQUIREMENTS

Space around Studio: 3 ft on every side

Indoor studios require a minimum 9ft ceiling to be installed under.

Outdoor Studios installed in locations potentially subject to very heavy snowfalls need to be located under a suitable overhead awning (minimum 10 ft / 3 m height) that minimises the volume of snow that can potentially accumulate on the roof of the studio. 

Studios need to be installed on a flat hard surface (outdoor studios need to be on a concrete pad, or equivalent, which needs to be suitable to potentially allow the studio to be dyna-bolted to the ground).

Compressor and Nitrogen Generator Plant Area: 10ft x 5ft (3m x 1.5m) area

Can be inside, potentially next to the studio, if in a well-ventilated room, otherwise outside (mounted on a skid we can provide), potentially up to 60ft away (if necessary), put preferably as close as possible to the studio.

USA ELECTRICAL REQUIREMENTS

Sufficient site power capacity will be required for the following dedicated electrical circuits.

  1. Infrared heating panels
    240 V, single-phase, 45 A dedicated circuit
  2. Compressor
    Preferred supply: 230 V, three-phase, 45 A dedicated circuit (note: if power supply is lower than 230 V ie. 208 V, a 60 amp dedicated circuit will be required). Where three-phase power is un-available a phase converter is used to allow the compressor to run on single-phase power
    240 V, single-phase, 90 A dedicated circuit
  3. Air-conditioning system
    240 V, single-phase, 20 A dedicated circuit
  4. Studio controls, circulation fans and TV display
    120 V, single-phase, 10 A dedicated circuit

Important operating requirement
The infrared heating system and nitrogen-generation compressor are not designed to operate simultaneously.

Depending on whether 230V 3-phase power is used or alternatively 208V 3-phase (or single-phase power), the total power draw requirement at any one time will be between 95 and 120 amps.

Final electrical service capacity, circuit protection, cable sizing, phase balancing and local compliance must be confirmed prior to installation by a licensed electrical contractor using the final equipment schedules and applicable local codes.